x

Flat Cables AWG 3 & 4 Core

  • Special Features
  • Construction
  • Applications
  • Benefits
  • Technical Details

Special Features:

  • Rubber Cable generally conforms to the requirement of CENELEC HD 22. l .S2, DIN VOE 0282PART 810, IEC 245,
    CEl20-l 9 & BS 6007, BS 6899.
  • PVC Cable generally conforms to the requirement of UL 83, IEC 60227, BS 6500, IS 694
  • Designed for heavy duty use.
  • Excellent resistance to oils, acids, chemicals, ozone & solvents.
  • Excellent weather resistance.
  • Excellent electrical properties.
  • Temperature Range: PVC Cable:-15°C to+ 70°C, Rubber Cable: -40°C to 90°C

Construction:

  • Conductor: Finely stranded bare flexible copper conductor.
  • Insulation: PVC/EPA Rubber
  • Sheath: PVC/EPA Rubber
  • Colour: 3 core : Red, Yellow, Black
    4 core : Red, Yellow, Black. Green

Applications:

  • For continuous use in deep well to supply power to submersible motors for the depth of up to 500 mtrs.

Benefits:

Industrial

Our pipes, hoses & fittings are specially design for industrial usage. Our product gives best performance while use in the factory. Due to high durability & flexibility our pipes & hoses are famous for industrial usage.

Quick assembly & maintenance free

The pipes, hoses & fittings are light in weight which results in extensive saving of time and laboring being Abrasion/Chemical resistance, free from rusting, pitting or scaling and maintenance-free.

Strong & Stiff

The pipes are specially designed for desire application which meets the required results as follows:

  • Superior strength with stiffness.
  • Flexible Compared to strength & stiffness.

SAGAR® Flat Cables AWG 3 & 4 Core Technical Specifications:

2 CORE FLAT SUBMERSIBLE PUMP CABLES (WITHOUT GROUND)
Conductor Size (AWG) Nos and Dia. of Wire (Nos x mm) Core Dia. (mm) Nominal Sheath Thickness (mm) Cable Overall Dimension (mm)
14 41/0.254 3.65 1.15 6.21 9.66
12 65/0.254 4.20 1.15 7.00 11.42
10 105/0.254 5.10 1.15 7.40 12.50
8 168/0.254 6.20 1.40 9.30 16.12
6 226/0.254 7.50 1.40 10.80 18.80
4 420/0.254 9.85 2.00 13.15 22.47
2 665/0.254 11.10 2.00 14.30 24.86
1 817/0.254 13.60 2.20 18.30 31.90
1/0 1045/0.254 13.60 2.20 18.30 31.90
2/0 1330/0.254 15.60 2.20 21.00 35.41
3/0 1672/0.254 18.00 2.40 23.50 42.99
4/0 2109/0.254 19.80 2.65 25.20 45.22
250 MCM 2503/0.254 21.50 2.80 28.00 48.53
3 CORE FLAT SUBMERSIBLE PUMP CABLE (WITHOUT GROUND) 1100 VOLTS
Conductor Size (AWG) Nos and Dia. of Wire (Nos x mm) Core Dia. (mm) Nominal Sheath Thickness (mm) Cable Overall Dimension (mm)
14 41/0.254 3.85 1.15 13.31x6.21
12 65/0.254 4.50 1.15 15.60 x 7.00
10 105/0.254 5.30 1.15 17.60x7.40
8 168/0.254 6.50 1.40 22.30 x 9.30
6 226/0.254 8.00 1.40 26.30 x 10.80
4 420/0.254 10.10 2.00 32.30x13.15
2 665/0.254 12.20 2.00 35.96 x 14.30
1 817/0.254 13.60 2.20 45.50 x 18.30
1/0 1045/0.254 13.60 2.20 45.50 x 18.30
2/0 1330/0.254 15.60 2.20 51 .00 x 21.00
3/0 1672/0.254 18.00 2.40 60.99 x 23.50
4/0 2116 x 0.254 19.80 2.65 65.00 x 25.20
250 MCM 2503 x 0.254 20.60 2.80 70.08 x 28.00

Note: The number of wires and diameter mentioned in the table are approximate and nominal; however they shall meet the requirements of conductor resistance as per standards.

4 CORE FLAT SUBMERSIBLE PUMP CABLES (WITH GROUND)
Conductor Size (AWG) Nos and Dia. of Wire (Nos x mm) Core Dia. (mm) Nominal Sheath Thickness (mm) Cable Overall Dimension (mm)
14 41/0.254 14 3.85 1.15 18.00 x 6.50
12 65/0.254 12 4.50 1.15 21.00 x 7.60
10 105/0.254 10 5.30 1.15 24.30 x 7.90
8 168/0.254 10 6.50 1.40 29.70 x 9.90
6 226/0.254 8 8.00 2.00 36.00 x 11 .80
4 420/0.254 8 10.10 2.00 45.10x14.70
2 665/0.254 6 12.20 2.00 50.10 x 16.20
1 817/0.254 6 13.60 2.20 58.10 x 19.00
1/0 1045/0.254 6 13.60 2.20 58.10x19.00
2/0 1330/0.254 4 15.60 2.20 66.50 x 21.50
3/0 1672/0.254 2 18.00 2.65 77.30 x 23.50
4/0 2116 x 0.254 19.80 3.85 87.00 x 27.80

Subscribe Our Newsletter