About CPVC Pipes, Fittings, Valves & Adhesives
Pipes
Fittings
Fittings SCH 80
Technical Details
Outside Diameters & Wall Thickness for SAGAR® CPVC 4120, SDR-11 Plastic Pipe as Per ASTM D-2846:
Nominal Size | Outside Diameter in (mm) | Wall Thickness in (mm) | Pressure Rating PSI (Kg/Cm²) | ||||||
---|---|---|---|---|---|---|---|---|---|
(inch) | (mm) | Average | Tolerance | Average | Tolerance | 73.4°C | 23°C | 23°C | 82°C |
½ | 15 | 0.625 (15.9) | ± 0.003 (0.08) | 0.068 (1.73) | ± 0.020 (0.51) | 400 | 28.1 | 100 | 7.0 |
3/4 | 20 | 0.875 (22.2) | ± 0.003 (0.08) | 0.080 (2.03) | ± 0.020 (0.51) | 400 | 28.1 | 100 | 7.0 |
1 | 25 | 1.125 (28.6) | ± 0.003 (0.08) | 0.102 (2.59) | ± 0.020 (0.51) | 400 | 28.1 | 100 | 7.0 |
1¼ | 32 | 1.375 (34.9) | ± 0.003 (0.08) | 0.125 (3.18) | ± 0.020 (0.51) | 400 | 28.1 | 100 | 7.0 |
1½ | 40 | 1.625 (41.3) | ± 0.004 (0.10) | 0.148 (3.76) | ± 0.020 (0.51) | 400 | 28.1 | 100 | 7.0 |
2 | 50 | 2.125 (54.0) | ± 0.004 (0.10) | 0.193 (4.90) | ± 0.023 (0.58) | 400 | 28.1 | 100 | 7.0 |
Outside Diameters & Wall Thickness for SAGAR® CPVC 4120, SDR-13.5 Plastic Pipe:
Nominal Size | Outside Diameter in (mm) | Wall Thickness in (mm) | Pressure Rating PSI (Kg/Cm²) | ||||||
---|---|---|---|---|---|---|---|---|---|
(inch) | (mm) | Average | Tolerance | Average | Tolerance | 73.4°C | 23°C | 23°C | 82°C |
½ | 15 | 0.625 (15.9) | ± 0.003 (0.08) | 0.055 (1.40) | ± 0.020 (0.51) | 320 | 22.5 | 80 | 5.6 |
3/4 | 20 | 0.875 (22.2) | ± 0.003 (0.08) | 0.065 (1.65) | ± 0.020 (0.51) | 320 | 22.5 | 80 | 5.6 |
1 | 25 | 1.125 (28.6) | ± 0.003 (0.08) | 0.083 (2.12) | ± 0.020 (0.51) | 320 | 22.5 | 80 | 5.6 |
1¼ | 32 | 1.375 (34.9) | ± 0.003 (0.08) | 0.102 (2.59) | ± 0.020 (0.51) | 320 | 22.5 | 80 | 5.6 |
1½ | 40 | 1.625 (41.3) | ± 0.004 (0.10) | 0.120 (3.06) | ± 0.020 (0.51) | 320 | 22.5 | 80 | 5.6 |
2 | 50 | 2.125 (54.0) | ± 0.004 (0.10) | 0.157 (4.00) | ± 0.023 (0.58) | 320 | 22.5 | 80 | 5.6 |
SAGAR® CPVC Plumbing Pipes Temperature De-Rating Factor :
The operating pressure of CPVC pipe will be reduced as the operating temperature increases above 23°C (73° F).To calculate this reduction, multiply the operating pressure with the correction factors shown below at a operating temperature of system :
Working Temp. (°F) | 73-80 | 90 | 100 | 120 | 140 | 160 | 180 | 200 |
---|---|---|---|---|---|---|---|---|
Working Temp. (°C) | 23-25 | 32 | 38 | 49 | 60 | 71 | 82 | 93 |
Pipe Derating Factor | 1.00 | 0.91 | 0.82 | 0.65 | 0.50 | 0.40 | 0.25 | 0.20 |
Valve Derating Factor | 1.00 | 0.95 | 0.90 | 0.80 | 0.70 | 0.61 | 0.63 | 0.45 |
Outside Diameter & Wall Thickness for SAGAR® Schedules 40 & 80 CPVC 4120 Pipe as Per ASTM F-441:
Nominal Size | Outside Diameter (mm) | Wall Thickness (mm) Schedule 40 |
Wall Thickness (mm) Schedule 80 |
||||
---|---|---|---|---|---|---|---|
(inch) | (mm) | Average | Tolerance | Min | Tolerance | Min | Tolerance |
½ | 15 | 0.840 | ± 0.004 (0.10) | ± 0.004 (0.10) | ± 0.004 (0.10) | ± 0.004 (0.10) | ± 0.004 (0.10) |
¾ | 20 | 1.050 | ± 0.004 (0.10) | ± 0.004 (0.10) | ± 0.004 (0.10) | ± 0.004 (0.10) | ± 0.004 (0.10) |
1 | 25 | 1.315 | ± 0.005 (0.13) | ± 0.005 (0.13) | ± 0.005 (0.13) | ± 0.005 (0.13) | ± 0.005 (0.13) |
1¼ | 32 | 1.660 | ± 0.005 (0.13) | ± 0.005 (0.13) | ± 0.005 (0.13) | ± 0.005 (0.13) | ± 0.005 (0.13) |
1½ | 40 | 1.900 | ± 0.006 (0.15) | ± 0.006 (0.15) | ± 0.006 (0.15) | ± 0.006 (0.15) | ± 0.006 (0.15) |
2 | 50 | 2.375 | ± 0.006 (0.15) | ± 0.006 (0.15) | ± 0.006 (0.15) | ± 0.006 (0.15) | ± 0.006 (0.15) |
2½ | 65 | 2.875 | ± 0.006 (0.15) | ± 0.006 (0.15) | ± 0.006 (0.15) | ± 0.006 (0.15) | ± 0.006 (0.15) |
3 | 80 | 3.500 | ± 0.007 (0.18) | ± 0.007 (0.18) | ± 0.007 (0.18) | ± 0.007 (0.18) | ± 0.007 (0.18) |
4 | 100 | 4.500 | ± 0.008 (0.20) | ± 0.008 (0.20) | ± 0.008 (0.20) | ± 0.008 (0.20) | ± 0.008 (0.20) |
5 | 125 | 5.563 | ± 0.010 (0.25) | -- | -- | ± 0.010 (0.25) | ± 0.010 (0.25) |
6 | 150 | 6.625 | ± 0.011 (0.28) | -- | -- | ± 0.011 (0.28) | ± 0.011 (0.28) |
8 | 200 | 8.625 | ± 0.015 (0.38) | -- | -- | ± 0.015 (0.38) | ± 0.015 (0.38) |
10 | 250 | 10.750 | ± 0.015 (0.38) | -- | -- | ± 0.015 (0.38) | ± 0.015 (0.38) |
12 | 300 | 12.750 | ± 0.015 (0.38) | -- | -- | ± 0.015 (0.38) | ± 0.015 (0.38) |
Pressure Rating @ 73 F (23 C) for SAGAR CPVC 4120, Schedule 40 & 80 Piping System as per ASTM F 441
Nominal Size | Pressure Required for Test* | Minimum Brust Pressure* | |||||||
---|---|---|---|---|---|---|---|---|---|
Schedule 40 | Schedule 80 | Schedule 40 | Schedule 80 | ||||||
(inch) | (mm) | psi | kPa | psi | kPa | psi | kPa | psi | kPa |
½ | 15 | 1250 | 8.620 | 1780 | 12.270 | 1910 | 13.170 | 2720 | 18.760 |
¾ | 20 | 1010 | 6.960 | 1440 | 9.930 | 1540 | 10.620 | 2200 | 15.170 |
1 | 25 | 950 | 6.550 | 1320 | 9.100 | 1440 | 9.930 | 2020 | 13.930 |
1¼ | 32 | 770 | 5.310 | 1090 | 7.520 | 1180 | 8.140 | 1660 | 11.450 |
1½ | 40 | 690 | 4.760 | 990 | 6.830 | 1060 | 7.310 | 1510 | 10.410 |
2 | 50 | 580 | 4.000 | 850 | 5.860 | 890 | 6.140 | 1290 | 8.890 |
2½ | 65 | 640 | 4.410 | 890 | 6.140 | 970 | 6.690 | 1360 | 9.380 |
3 | 80 | 590 | 4.070 | 790 | 5.450 | 840 | 5.790 | 1200 | 8.270 |
4 | 100 | 470 | 3.240 | 680 | 4.690 | 710 | 5.310 | 1040 | 7.170 |
5 | 125 | -- | -- | 610 | 4.210 | -- | -- | 930 | 6.410 |
6 | 150 | -- | -- | 590 | 4.070 | -- | -- | 890 | 6.140 |
8 | 200 | -- | -- | 520 | 3.590 | -- | -- | 790 | 5.450 |
10 | 250 | -- | -- | 490 | 3.380 | -- | -- | 750 | 5.170 |
12 | 300 | -- | -- | 480 | 3.310 | -- | -- | 730 | 5.030 |
Support Spacing
SAGAR® CPVC Pipes Recommended Support Spacing:
Nominal Pipe Size | Horizontal & Vertical Support Spacing | ||||||||
---|---|---|---|---|---|---|---|---|---|
21°C (70°F) | 49°C (120°F) | 71°C (160°F) | 82°C (180°F) | ||||||
(mm) | (inch) | (CM) | (Ft.) | (CM) | (Ft.) | (CM) | (Ft.) | (CM) | (Ft.) |
15 | ½ | 5.5 | 167.70 | 4.5 | 137.16 | 3.0 | 91.44 | 2.5 | 76.20 |
20 | 3/4 | 5.5 | 167.70 | 5.0 | 152.40 | 3.0 | 91.44 | 2.5 | 76.20 |
25 | 1 | 6.0 | 182.88 | 5.5 | 167.70 | 3.5 | 106.68 | 3.5 | 91.44 |
32 | 1¼ | 6.5 | 198.12 | 6.0 | 182.88 | 3.5 | 106.68 | 3.5 | 106.68 |
40 | 1½ | 7.0 | 213.36 | 6.0 | 182.88 | 3.5 | 106.68 | 3.5 | 106.68 |
50 | 2 | 7.0 | 213.36 | 6.5 | 198.12 | 4.0 | 121.92 | 3.5 | 106.68 |
Basic Physical Properties
Property | ASTM Test | Condition | English Units | SI Units |
---|---|---|---|---|
General | ||||
Specific Gravity | D-792 | 73°F / 23°C | 1.55 g/cm² | 1.55 g/cm2 |
Specific Volume | 73°F / 23°C | 0.645 cm²/g | 0.645 cm2/g | |
Water Absorption | D-570 | 73°F / 23°C | +0.03% | +0.03% |
212°F / 100°C | +0.55% | +0.55% | ||
Rockwell Hardness | D-785 | 73°F / 23°C | 119 | |
Cell Class | D-1784 | 23447-B | ||
General | ||||
Izod Impact | D-256 | 73°F / 23°C | 1.5ft lbs/in o.n | 80 j / m o.n |
Tensile Strength | D-638 | 73°F / 23°C | 8000 psi | 55 N / mm² |
Tensile Modulus | D-638 | 73°F / 23°C | 360,000 psi | 2500 N / mm² |
Flexural Strength | D-790 | 73°F / 23°C | 15,100 psi | 104 N / mm² |
Flexural Modulus | D-790 | 73°F / 23°C | 415,000 psi | 2860 N / mm² |
Compressive Strength | D-695 | 73°F / 23°C | 10,100 psi | 70 N / mm² |
Compressive Modulus | D-695 | 73°F / 23°C | 196,000 psi | 1350 N / mm² |
General | ||||
Coefficient of Thermal | D-696 | 3.4x10-3 in/in/°F | 6.3x103 m/m/°K | |
Expansion | ||||
Thermal Conductivity | C-177 | 0.95 BTU in/hr/ft³/°F | 014wm/°K/m³ | |
Heat Distortion Temperature | D-638 | 217°F | 103°C | |
Heat Capacity | DCS | 73°F / 23°C | 0.21 BTU / lb°F | 0.90 j/g°K |
212°F / 100°C | 0.26 BTU / lb°F | 1.10 j/g°K | ||
General | ||||
Flammability Rating | UL-94 | 0.062 in / 0.157 cm | V-0, 5VB, 5VA | |
Flame Spread | E-84 | 15 | ||
Smoke Developed | E-84 | 70-125 | ||
Limiting Oxygen Index | D-2863 | 60% | ||
General | ||||
Dielectric Strength | D-147 | 1250 V/mil | 492,000 V/cm | |
Dielectric Constant | D-150 | 60 Hz, 30°F / -1°C | 3.70 | 3.70 |
Power Factor | D-150 | 1000 Hz | 0.007% | 0.007% |
Volume Resistivity | D-257 | 73°F / 23°C | 3.4x1015 ohm / cm | 3.4x1015 ohm / cm |
CPVC Fittings Dimensions

Trapered Socket Dimensions for CPVC 4120, SDR 11, Plastic Pipe Fittings as Per ASTM D2846:
Nominal Size | Socket Entrance Diameter in (mm) | Socket Bottom Diameter in (mm) | Socket Length | Inside Diameter in (mm) | Socket Enterance "EA" min. | Socket Bottom "EB" min. | "F" | |||
---|---|---|---|---|---|---|---|---|---|---|
(mm) | (inch) | "A" Average | "A' Tolerance | "A" Average | "A" Tolerance | "C" min | "D" min | Wall Thickness in (mm) | ||
15 | ½ | 0.633(16.08) | ±0.003(0.08) | 0.619(15.72) | ±0.003(0.08) | 0.500(12.70) | 0.489(12.42) | 0.068(1.73) | 0.102(2.59) | 0.128(3.25) |
20 | 3/4 | 0.884(22.45) | ±0.003(0.08) | 0.870(22.10) | ±0.003(0.08) | 0.700(17.78) | 0.715(18.16) | 0.080(2.03) | 0.102(2.59) | 0.128(3.25) |
25 | 1 | 1.135(28.83) | ±0.003(0.08) | 1.121(28.47) | ±0.003(0.08) | 0.900(22.86) | 0.921(23.39) | 0.102(2.59) | 0.102(2.59) | 0.128(3.25) |
32 | 1¼ | 1.386(35.20) | ±0.003(0.08) | 1.372(34.85) | ±0.003(0.08) | 1.100(27.94) | 1.125(28.58) | 1.125(3.18) | 0.125(3.18) | 0.156(3.96) |
40 | 1½ | 1.640(41.66) | ±0.004(0.10) | 1.622(41.20) | ±0.004(0.10) | 1.300(33.02) | 1.329(33.76) | 1.148(3.76) | 0.148(3.76) | 0.185(4.70) |
50 | 2 | 2.141(54.38) | ±0.004(0.10) | 2.123(53.92) | ±0.004(0.10) | 1.700(43.18) | 1.739(44.17) | 1.193(4.90) | 0.193(4.90) | 0.241(6.12) |

Minimum Dimensions from Center to End of Socket (Laying Length) for CPVC 4120, SDR 11, Plastic Tubing Fittings as Per ASTM D2846:
Nominal Size | (G) Min. | (J) Min. | (N) Min. | |
---|---|---|---|---|
(mm) | (inch) | |||
15 | ½ | 0.382 | 0.183 | 0.102 |
20 | 3/4 | 0.507 | 0.235 | 0.102 |
25 | 1 | 0.633 | 0.287 | 0.102 |
32 | 1¼ | 0.758 | 0.339 | 0.102 |
40 | 1½ | 0.884 | 0.391 | 0.102 |
50 | 2 | 1.134 | 0.495 | 0.102 |
CPVC Fittings Standard
Threads (NPT) ANSI Standard B1.20.1
Nominal (mm) | Size (in.) | Threads Per in. | Effective ThreadLength L | Pitch of Thread P |
---|---|---|---|---|
15 | ½ | 14 | 0.5337 | 0.07143 |
20 | 3/4 | 14 | 0.5457 | 0.07143 |
25 | 1 | 11½ | 0.6828 | 0.08696 |
32 | 1¼ | 11½ | 0.7068 | 0.08696 |
40 | 1½ | 11½ | 0.7235 | 0.08696 |
50 | 2 | 11½ | 0.7565 | 0.08696 |
65 | 2½ | 8 | 1.1375 | 0.12500 |
80 | 3 | 8 | 1.2000 | 0.12500 |
100 | 4 | 8 | 1.3000 | 0.12500 |
BSP ISO 7/1 Parallel Threads
Nominal (mm) |
Size (in.) |
Threads Per in. |
Effective ThreadLength L |
Pitch of Thread P |
---|---|---|---|---|
15 | ½ | 14 | 13.152 | 1.8143 |
20 | 3/4 | 14 | 14.514 | 1.8143 |
25 | 1 | 11 | 16.714 | 2.3091 |
32 | 1¼ | 11 | 19.050 | 2.3091 |
40 | 1½ | 11 | 19.050 | 2.3091 |
50 | 2 | 11 | 23.378 | 2.3091 |
65 | 2½ | 11 | 26.698 | 2.3091 |
80 | 3 | 11 | 29.873 | 2.3091 |
100 | 4 | 11 | 35.791 | 2.3091 |
Friction Loss and Flow velocity
Friction Loss and Flow velocity for SDR 11 CTC CPVC Thermoplastic Pipe
(Friction head and Friction Loss are per 100 feet of pipe)
NOTICE : Flow velocity should not exceed 5 feet per second. Velocities in excess of 5 feet per second may result in system failure and property damage.
Gallons Per Minute | Velocity Feet Per Second | Head Loss Feet of Water Per 100 Ft. | Pressure Loss PSI Per 100 Ft. | Velocity Feet Per Second | Head Loss Feet of Water Per 100 Ft. | Pressure Loss PSI Per 100 Ft. | Velocity Feet Per Second | Head Loss Feet of Water Per 100 Ft. | Pressure Loss PSI Per 100 Ft. | Velocity Feet Per Second | Head Loss Feet of Water Per 100 Ft. | Pressure Loss PSI Per 100 Ft. | Velocity Feet Per Second | Head Loss Feet of Water Per 100 Ft. | Pressure Loss PSI Per 100 Ft. | Velocity Feet Per Second | Head Loss Feet of Water Per 100 Ft. | Pressure Loss PSI Per 100 Ft. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1½ in. | ¾ in. | 1 in. | 1 ¼ | 1½ in. | 2 in. | |||||||||||||
1 | 1.71 | 3.19 | 1.38 | 0.80 | 0.50 | 0.22 | 0.48 | 0.15 | 0.06 | - | - | - | - | - | - | - | - | - |
2 | 3.42 | 11.53 | 5.00 | 1.60 | 1.82 | 0.79 | 0.96 | 0.53 | 0.23 | - | - | - | - | - | - | - | - | - |
3 | 5.16 | 24.43 | 10.59 | 2.40 | 3.85 | 1.67 | 1.44 | 1.12 | 0.49 | - | - | - | - | - | - | - | - | - |
4 | 6.83 | 41.62 | 18.04 | 3.20 | 6.55 | 2.84 | 1.93 | 1.91 | 0.83 | - | - | - | - | - | - | - | - | - |
5 | 8.54 | 62.91 | 27.27 | 4.00 | 9.91 | 4.29 | 2.41 | 2.89 | 1.25 | 1.61 | 1.09 | 0.47 | 0.16 | 0.49 | 0.21 | 0.68 | 0.13 | 0.06 |
6 | 10.25 | 88.18 | 38.23 | 4.79 | 13.89 | 6.02 | 2.89 | 4.05 | 1.76 | - | - | - | - | - | - | - | - | - |
7 | 11.96 | 117.32 | 50.86 | 5.59 | 18.47 | 8.01 | 3.37 | 5.39 | 2.34 | - | - | - | - | - | - | - | - | - |
8 | 13.67 | 150.23 | 65.13 | 6.39 | 23.66 | 10.26 | 3.85 | 6.90 | 2.99 | - | - | - | - | - | - | - | - | - |
9 | 15.38 | 186.85 | 81.00 | 7.19 | 29.42 | 12.76 | 4.33 | 8.59 | 3.72 | - | - | - | - | - | - | - | - | - |
10 | 17.08 | 227.11 | 98.45 | 7.99 | 35.76 | 15.50 | 4.82 | 10.43 | 4.52 | 3.23 | 3.94 | 1.71 | 2.31 | 1.75 | 0.76 | 1.35 | 0.49 | 0.21 |
15 | 11.99 | 75.78 | 32.85 | 7.22 | 22.11 | 9.58 | 4.84 | 8.35 | 3.62 | 3.47 | 3.71 | 1.61 | 2.03 | 1.03 | 0.45 | |||
20 | 15.98 | 129.11 | 55.97 | 9.63 | 37.67 | 16.33 | 6.46 | 14.23 | 6.17 | 4.63 | 6.33 | 2.74 | 2.70 | 1.76 | 0.76 | |||
25 | 12.04 | 56.94 | 24.69 | 8.07 | 21.51 | 9.33 | 5.78 | 9.56 | 4.15 | 3.38 | 2.66 | 1.15 | ||||||
30 | 14.45 | 79.82 | 34.60 | 9.68 | 30.15 | 13.07 | 6.94 | 13.40 | 5.81 | 4.05 | 3.73 | 1.62 | ||||||
35 | 16.86 | 106.19 | 46.03 | 11.30 | 40.11 | 17.39 | 8.09 | 17.83 | 7.73 | 4.73 | 4.96 | 2.15 | ||||||
40 | 12.91 | 51.37 | 22.27 | 9.25 | 22.83 | 9.90 | 5.40 | 6.35 | 2.75 | |||||||||
45 | 14.52 | 63.89 | 27.70 | 10.41 | 28.40 | 12.31 | 6.08 | 7.89 | 3.42 | |||||||||
50 | 16.14 | 77.66 | 33.66 | 11.56 | 34.52 | 14.96 | 6.75 | 9.60 | 4.16 | |||||||||
55 | 17.75 | 92.65 | 40.16 | 12.72 | 41.18 | 17.85 | 7.43 | 11.45 | 4.96 | |||||||||
60 | 13.88 | 48.38 | 20.97 | 8.10 | 13.45 | 5.83 | ||||||||||||
70 | 16.19 | 64.37 | 27.90 | 9.46 | 17.89 | 7.76 | ||||||||||||
80 | 10.61 | 22.91 | 9.93 | |||||||||||||||
90 | 12.16 | 28.50 | 12.35 | |||||||||||||||
100 | 13.51 | 34.64 | 15.02 | |||||||||||||||
125 | 16.89 | 52.37 | 22.70 |
CPVC Pipes & Fittings Joining Instructions

Cutting
If necessary, cut the ends of pipe square. Cutting the pipe as squarely as possible provides the surface of the pipe with a maximum bonding area. If whole pipe is to be assembled, there is no need for cutting the pipe.

Bevelling/Deburring
Burrs can prevent contact between pipe and fitting during assembly. So use chamfering tool or file to remove the burrs from outside and inside surfaces of the pipe. For easy entry of the pipe into the socket and to minimize the chances of wiping PVC cement from the socket, a slight bevel of about 10º-15º shall be placed at the end of pipe.

Joining Preparation
Keep ready all the pipes and fittings which are to be joined, inspect them for any damage or irregularities. Check dry fit of pipe and fitting. Pipe should easily go 1/4 to 3/4 way in into the fitting.

PVC Cement Application
PVC cement is to be applied on clean surfaces and while primer is still tacky. It is to be applied with proper applicator on the O.D. of the pipe end, equal to the depth of the fitting socket. Coat of PVC cement should be even and heavy enough to fill any gap. If necessary, apply second coat. Apply medium coat to the fitting socket with a suitable applicator. Avoid pudding.

Assembly
Assemble the cemented parts quickly while cement is wet. If interrupted, recoat both parts. Push pipe fully into fitting by twisting 1/8 to 1/4 turn. To avoid pushout, hold the assembly for about 60 seconds. Excess cement should be wiped off by cloth. A continuous bead of solvent cement should be the evidence of properly joining of pipes & fittings.

Set & Cure Times
Assembled joints should not be disturbed. PVC cement set and cure times depends upon the cement type used, pipe size, temperature, relative humidity and tightness of fit. Drying time is faster for drier environments, smaller pipe sizes, high temperatures and tighter fits.
Features & Benefits
CPVC Pipes
Note:
- Valves, Unions and Specialty Products have different elevated temperature ratings than pipes.
- For obtaining working pressure in system, multiply the maximum pressure with derating factor at the working temperature of system.
CPVC Schedule 40 & 80 Pipes
Application:
- Building Construction.
- Sanitary Application.
- Portable Water Supply
- Industrial Application
Note:
- Non Standard wall thickness, length and color can also be offered If desired.
- Pipes can also be offered as per DIN 8062, ISO 4422-2, BS 3505/6.
For HOT & COLD Water Application
Corrosion resistance:
SAGAR CPVC Pipe gives excellent resistance even under the harshest of water conditions so there are none of the purity worries from corrosion of metal pipe or soldered joints. SAGAR CPVC Pipe keeps pure water pure.
Lower bacterial growth:
Bacteria build up with CPVC is far lower than with alternative piping materials - Copper, Steel and other thermoplastics.
No Scale, pit or leach formation:
Even after years of use in the most aggressive conditions, SAGAR CPVC pipe won’t corrode, standing up to low pH water, coastal salt air exposures and corrosive soils. SAGAR CPVC Pipe stays as solid and reliable as the day it was installed. It maintains full water carrying Capacity because its scale resistance means no build up to cause water pressure loss.
Unaffected by chlorine in the water:
Some materials may be adversely affected by chlorine contained in the water supply, which can cause breakdown of the polymer chains and potential leaks. In this respect, SAGAR CPVC pipe is unaffected by the chlorine present in potable water supply.
Low thermal expansion:
SAGAR CPVC pipe has a lower coefficient of thermal expansion than alternative plastics, reducing the amount that the pipe expands when hot water is running, again reducing unsightly ‘looping’ of the pipe.
Easy Plumbing process:
CPVC uses a simple, solvent cement jointing method. Tools required are very simple and inexpensive (chamfering tool and pipe cutter only) and avoid the need for an electrical source. Superior insulation : SAGAR CPVC pipe is more energy efficient than metal pipe. As an insulator it does not lose heat the way metal pipe do. Heat loss and thermal expansion are reduced. Superior insulation :
Hot water compatible:
SAGAR CPVC pipe is compatible with both hot and cold water. It withstand very high temperature compared to any other thermoplastic plumbing systems. Many solar and electric water heaters have CPVC piping system for heat efficiency and lower installation cost.
Tough, rigid material:
SAGAR CPVC pipe has a much higher strength than other thermoplastics used in plumbing. This means that CPVC needs less hangers and supports and there is no unsightly looping of the pipe. SAGAR CPVC pipe Has a higher pressure bearing capability. This leads to the same flow rate with a smaller pipe size.
Fire safety:
CPVC has a limiting Oxygen Index (LOI) of 60. Thus in air, SAGAR CPVC pipe does not support combustion. No flaming drips, does not increase the fire load, low flame spread, low smoke generation.
Approved world wide:
CPVC plumbing system is approved for contact with potable water in wide range of countries including USA, UK, Canada, Germany, France, The Netherlands, Middle East among others. Here in India, SAGAR CPVC plumbing system is approved by BMC and CPWD for potable water supply.